Portal›Task List Library
Standard Maintenance Task List
Corporate maintenance task master. Each task retains work purpose, trigger, execution mode, acceptance criteria and reference standard.
Tasklist Master314 tasks
| Task ID | Equipment Group | Discipline | Strategy Element | Task / Purpose | Frequency | Condition | SAP Execution | Reference |
|---|---|---|---|---|---|---|---|---|
| CV-MARINE-CERT-01 | Jetty / Marine / Barge / Mooring | CIVL/Marine | Statutory / Certification | Marine / Jetty Statutory Inspection / Certification Marine / Jetty Statutory Inspection / Certification | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | Marine structural integrity / class / statutory |
| UT-HVAC-CERT-01 | HVAC / Refrigeration / Chiller | HVAC | Statutory / Certification | HVAC / Refrigeration Statutory Inspection / Certification HVAC / Refrigeration Statutory Inspection / Certification | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | OEM / condition / refrigerant rules |
| SF-FIRE-FT-02 | Fire Fighting / Fire Water / Foam Equipment | FIRE | Functional / Proof / Performance Test | Fire Pump / Deluge / Monitor Performance Test Fire Pump / Deluge / Monitor Performance Test | Periodic / ITM Due | ONLINE | 03 - PACKAGE WO | NFPA 25 / site fire philosophy |
| ST-TANK-CRYO-CERT-02 | Cryogenic / Refrigerated Storage Tank | MSTA/INTY | Statutory / Certification | Cryogenic / Refrigerated Storage Tank Statutory / Authorized Inspection Cryogenic / Refrigerated Storage Tank Statutory / Authorized Inspection | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | API 625 / API 620 / RBI / Company Standard |
| ST-SPHERE-CERT-01 | Pressure Sphere | MSTA/INTY | Statutory / Certification | Pressure Sphere Statutory / Authorized Inspection Pressure Sphere Statutory / Authorized Inspection | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | API 510 / RBI / Company Standard |
| ST-BOILER-CERT-01 | Boiler | MSTA/INTY | Statutory / Certification | Boiler Statutory / Authorized Inspection Boiler Statutory / Authorized Inspection | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | API RP 573 / statutory boiler rules / OEM |
| ST-HEATER-CERT-01 | Fired Heater / Furnace | MSTA/INTY | Statutory / Certification | Fired Heater / Furnace Statutory / Authorized Inspection Fired Heater / Furnace Statutory / Authorized Inspection | Statutory Due | ONLINE / SHUTDOWN | 02 - NOTIFICATION ONLY | API RP 573 / RBI / OEM |
| ST-VESSEL-NP-INS-01 | Non-Pressure Process Vessel | MSTA/INTY | Inspection / Integrity | Non-Pressure Process Vessel Routine Condition Inspection Non-Pressure Process Vessel Routine Condition Inspection | Periodic / Condition | ONLINE | 02 - NOTIFICATION ONLY | Company integrity standard / service-specific |
| ST-VESSEL-NP-PM-01 | Non-Pressure Process Vessel | MSTA/INTY | Preventive Maintenance | Non-Pressure Process Vessel Preventive Service Non-Pressure Process Vessel Preventive Service | OEM / Usage / Condition | ONLINE / SHUTDOWN | 03 - PACKAGE WO | Company integrity standard / service-specific |
| ST-VESSEL-NP-CM-01 | Non-Pressure Process Vessel | MSTA/INTY | Condition / Performance Monitoring | Non-Pressure Process Vessel Condition / Performance Monitoring Non-Pressure Process Vessel Condition / Performance Monitoring | Continuous / Route | ONLINE | 01 - MONITORING ONLY | Company integrity standard / service-specific |
| ST-VESSEL-NP-FT-01 | Non-Pressure Process Vessel | MSTA/INTY | Functional / Proof / Performance Test | Non-Pressure Process Vessel Functional / Performance Test Non-Pressure Process Vessel Functional / Performance Test | Test Due / Condition | ONLINE | 02 - NOTIFICATION ONLY | Company integrity standard / service-specific |
| ST-VESSEL-NP-OVH-01 | Non-Pressure Process Vessel | MSTA/INTY | Restoration / Overhaul | Non-Pressure Process Vessel Condition-Triggered Repair / Restoration Non-Pressure Process Vessel Condition-Triggered Repair / Restoration | Condition Triggered | SHUTDOWN | 04 - INDIVIDUAL WO | Company integrity standard / service-specific |
| ZZ-RECLASSIFY-DATA-01 | Unclassified Asset | DATA | Inspection / Integrity | RECLASSIFY ASSET BEFORE TASKLIST ASSIGNMENT RECLASSIFY ASSET BEFORE TASKLIST ASSIGNMENT | No Maintenance Plan | N/A | 01 - MONITORING ONLY | ISO 14224 taxonomy / company master-data governance |
| GOV-RTF-01 | Run-to-Failure Governance | GOV | Run-to-Failure | Run-to-Failure / Corrective-Only Governance Run-to-Failure / Corrective-Only Governance | No Routine Plan | N/A | 07 - RTF / CORRECTIVE ONLY | RCM / company risk & maintenance strategy governance |
Halaman 13 / 13