Portal›Task List Library

Standard Maintenance Task List

Corporate maintenance task master. Each task retains work purpose, trigger, execution mode, acceptance criteria and reference standard.

Tasklist Master314 tasks
Task IDEquipment GroupDisciplineStrategy ElementTask / PurposeFrequencyConditionSAP ExecutionReference
ST-SPHERE-INS-02Pressure SphereMSTA/INTYInspection / Integrity
Pressure Sphere Internal Inspection / NDE
Pressure Sphere Internal Inspection / NDE
RBI / TASHUTDOWN06 - TA / SHUTDOWN PACKAGEAPI 510 / RBI / Company Standard
ST-SPHERE-OVH-01Pressure SphereMSTA/INTYRestoration / Overhaul
Pressure Sphere Condition-Triggered Repair
Pressure Sphere Condition-Triggered Repair
Condition / TASHUTDOWN04 - INDIVIDUAL WOAPI 510 / API 579 as applicable
ST-HX-CM-01Heat ExchangerMSTA/INTYCondition / Performance Monitoring
Heat Exchanger Fouling / Performance Monitoring
Heat Exchanger Fouling / Performance Monitoring
Continuous / Monthly ReviewONLINE01 - MONITORING ONLYAPI 510 / API 660 family / RBI
ST-HX-INS-01Heat ExchangerMSTA/INTYInspection / Integrity
Heat Exchanger External Integrity Inspection
Heat Exchanger External Integrity Inspection
RBI / Code DueONLINE02 - NOTIFICATION ONLYAPI 510 / API 660 family / RBI
ST-HX-INS-02Heat ExchangerMSTA/INTYInspection / Integrity
Heat Exchanger Internal / Tube Inspection
Heat Exchanger Internal / Tube Inspection
RBI / TASHUTDOWN06 - TA / SHUTDOWN PACKAGEAPI 510 / API 660 family / RBI
ST-HX-PM-01Heat ExchangerMSTA/INTYPreventive Maintenance
Heat Exchanger Cleaning / Fouling Removal
Heat Exchanger Cleaning / Fouling Removal
Condition / TASHUTDOWN03 - PACKAGE WOAPI 510 / API 660 family / RBI
ST-HX-OVH-01Heat ExchangerMSTA/INTYRestoration / Overhaul
Heat Exchanger Bundle / Gasket / Tube Repair
Heat Exchanger Bundle / Gasket / Tube Repair
Condition / TASHUTDOWN04 - INDIVIDUAL WOAPI 510 / API 660 family / RBI
ST-ACHE-INS-01Air-Cooled Heat ExchangerMSTA/INTYInspection / Integrity
ACHE External / Structural / Header Inspection
ACHE External / Structural / Header Inspection
RBI / ConditionONLINE02 - NOTIFICATION ONLYAPI 661 / RBI / OEM
ST-ACHE-CM-01Air-Cooled Heat ExchangerMSTA/INTYCondition / Performance Monitoring
ACHE Thermal / Air-Side Performance Monitoring
ACHE Thermal / Air-Side Performance Monitoring
Continuous / Monthly ReviewONLINE01 - MONITORING ONLYAPI 661 / RBI / OEM
ST-ACHE-PM-01Air-Cooled Heat ExchangerMSTA/INTYPreventive Maintenance
ACHE Fan / Belt / Gearbox / Fin Cleaning Service
ACHE Fan / Belt / Gearbox / Fin Cleaning Service
Condition / Annual ReviewONLINE / SHUTDOWN03 - PACKAGE WOAPI 661 / RBI / OEM
ST-ACHE-OVH-01Air-Cooled Heat ExchangerMSTA/INTYRestoration / Overhaul
ACHE Fan / Header / Bundle Condition-Triggered Repair
ACHE Fan / Header / Bundle Condition-Triggered Repair
Condition / TASHUTDOWN04 - INDIVIDUAL WOAPI 661 / RBI / OEM
ST-PIPING-INS-01Process PipingMSTA/INTYInspection / Integrity
Piping External Visual Inspection by Circuit
Piping External Visual Inspection by Circuit
RBI / Code DueONLINE02 - NOTIFICATION ONLYAPI 570 / API 580/581
ST-PIPING-INS-02Process PipingMSTA/INTYInspection / Integrity
Piping Thickness Monitoring / TML Survey
Piping Thickness Monitoring / TML Survey
RBI / Corrosion DueONLINE02 - NOTIFICATION ONLYAPI 570 / API 580/581
ST-PIPING-CM-01Process PipingMSTA/INTYCondition / Performance Monitoring
Piping Vibration / Movement / Support Surveillance
Piping Vibration / Movement / Support Surveillance
Condition / RouteONLINE02 - NOTIFICATION ONLYAPI 570 / API 580/581
ST-PIPING-OVH-01Process PipingMSTA/INTYRestoration / Overhaul
Piping Condition-Triggered Repair / Replacement
Piping Condition-Triggered Repair / Replacement
Condition / TASHUTDOWN04 - INDIVIDUAL WOAPI 570 / API 580/581
ST-HEATER-INS-01Fired Heater / FurnaceMSTA/INTYInspection / Integrity
Fired Heater / Furnace External / On-Stream Inspection
Fired Heater / Furnace External / On-Stream Inspection
Inspection DueONLINE02 - NOTIFICATION ONLYAPI RP 573 / RBI / OEM
ST-HEATER-INS-02Fired Heater / FurnaceMSTA/INTYInspection / Integrity
Fired Heater / Furnace Internal / Tube / Refractory Inspection
Fired Heater / Furnace Internal / Tube / Refractory Inspection
TA / Inspection DueSHUTDOWN06 - TA / SHUTDOWN PACKAGEAPI RP 573 / RBI / OEM
ST-HEATER-CM-01Fired Heater / FurnaceMSTA/INTYCondition / Performance Monitoring
Fired Heater / Furnace Combustion / Efficiency / Tube Temperature Monitoring
Fired Heater / Furnace Combustion / Efficiency / Tube Temperature Monitoring
Continuous / Monthly ReviewONLINE01 - MONITORING ONLYAPI RP 573 / RBI / OEM
ST-HEATER-FT-01Fired Heater / FurnaceMSTA/INTYFunctional / Proof / Performance Test
Fired Heater / Furnace Burner / BMS Functional Test
Fired Heater / Furnace Burner / BMS Functional Test
Proof-Test DueONLINE / SHUTDOWN03 - PACKAGE WOAPI RP 573 / RBI / OEM
ST-HEATER-PM-01Fired Heater / FurnaceMSTA/INTYPreventive Maintenance
Fired Heater / Furnace Burner / Soot / Draft Equipment Preventive Service
Fired Heater / Furnace Burner / Soot / Draft Equipment Preventive Service
Condition / Annual ReviewONLINE / SHUTDOWN03 - PACKAGE WOAPI RP 573 / RBI / OEM
ST-HEATER-OVH-01Fired Heater / FurnaceMSTA/INTYRestoration / Overhaul
Fired Heater / Furnace Condition-Triggered Tube / Refractory / Burner Repair
Fired Heater / Furnace Condition-Triggered Tube / Refractory / Burner Repair
Condition / TASHUTDOWN06 - TA / SHUTDOWN PACKAGEAPI RP 573 / RBI / OEM
ST-BOILER-INS-01BoilerMSTA/INTYInspection / Integrity
Boiler External / On-Stream Inspection
Boiler External / On-Stream Inspection
Inspection DueONLINE02 - NOTIFICATION ONLYAPI RP 573 / statutory boiler rules / OEM
ST-BOILER-INS-02BoilerMSTA/INTYInspection / Integrity
Boiler Internal / Tube / Refractory Inspection
Boiler Internal / Tube / Refractory Inspection
TA / Inspection DueSHUTDOWN06 - TA / SHUTDOWN PACKAGEAPI RP 573 / statutory boiler rules / OEM
ST-BOILER-CM-01BoilerMSTA/INTYCondition / Performance Monitoring
Boiler Combustion / Efficiency / Tube Temperature Monitoring
Boiler Combustion / Efficiency / Tube Temperature Monitoring
Continuous / Monthly ReviewONLINE01 - MONITORING ONLYAPI RP 573 / statutory boiler rules / OEM
ST-BOILER-FT-01BoilerMSTA/INTYFunctional / Proof / Performance Test
Boiler Burner / BMS Functional Test
Boiler Burner / BMS Functional Test
Proof-Test DueONLINE / SHUTDOWN03 - PACKAGE WOAPI RP 573 / statutory boiler rules / OEM
Halaman 2 / 13