Portal›Maintenance Plan
Maintenance Plan Engineering
Converts approved task logic into scheduling / trigger rules and lean SAP execution. Not every maintenance activity requires a cyclic work order.
Registered Plans - Assets
36.036
16.0% coverage
Plan Engineering Rows
314
One per maintenance task
SAP Plan Patterns
8
PA-01 through PA-08 plan patterns
Actual Call-Detail Assets
19.574
Matched from RU Sheet2
SAP Plan Patterns
| Code | Plan Pattern | Use Case | Call Object | Routine Plan? | Default Grouping | Task Rows |
|---|---|---|---|---|---|---|
| PA-01 | Monitoring / No Routine SAP Plan | Continuous/online monitoring; exception-driven action | None | No | System/area monitoring route | 37 |
| PA-02 | Inspection / Routine Notification | Simple inspection / due-date / condition route | Notification | Yes | Route/circuit/area/due window | 120 |
| PA-03 | Test / Calibration Notification | Simple test/calibration/proving | Notification | Yes | Unit + discipline + method + due window | 12 |
| PA-04 | Campaign / Package WO | Repetitive work needing resources / permit / vendor | Package WO | Yes | Area/unit + discipline/vendor + common window | 76 |
| PA-05 | Individual Planned WO | Unique asset-specific scheduled work | Individual WO | Yes | Equipment-specific | 0 |
| PA-06 | TA / Shutdown Package | Intrusive work requiring outage/TA | Package WO | Conditional | TA/unit/system/work package | 14 |
| PA-07 | Condition-Triggered WO | Repair/restoration from finding/diagnostic | Individual WO | No routine cyclic plan | Finding/equipment/defect | 54 |
| PA-08 | RTF / Corrective | Approved failure-event workflow | Corrective Notification / WO | No preventive plan | Equipment/failure event | 1 |
Maintenance Plan Engineering Library - Task ID deep-links back to the Task List.314 rows
| Task ID | Family | Task Title | Final Frequency / Trigger Rule | Owner | Plan Pattern | SAP Plan Type | Call Object | Routine? |
|---|---|---|---|---|---|---|---|---|
| IN-CONTROL-SYS-INS-01 | DCS / PLC / SIS / Control System | DCS / PLC / SIS / Control System Visual / Installation Inspection | Use approved route interval based on P-F interval / history; no universal cycle. | Inspection / Asset Integrity | PA-02 INSPECTION / ROUTINE NOTIFICATION | Due-date / single-cycle / strategy notification plan | Notification | Yes |
| IN-CONTROL-SYS-CM-01 | DCS / PLC / SIS / Control System | DCS / PLC / SIS / Control System Diagnostic / Performance Surveillance | Continuous monitoring + periodic engineering review at approved site interval. | Reliability / Condition Monitoring | PA-01 MONITORING / NO ROUTINE SAP PLAN | No routine SAP plan | None | No |
| IN-CONTROL-SYS-FT-01 | DCS / PLC / SIS / Control System | DCS / PLC / SIS / Control System Functional / Loop / Performance Test | Per approved proof/functional-test interval; condition can trigger earlier. | Reliability + Discipline | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-CONTROL-SYS-CAL-01 | DCS / PLC / SIS / Control System | DCS / PLC / SIS / Control System Calibration / Metrological Verification | Per approved metrology / drift-history / criticality calibration interval. | Instrument / Metrology | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-CONTROL-SYS-OVH-01 | DCS / PLC / SIS / Control System | DCS / PLC / SIS / Control System Condition-Triggered Repair / Restoration | Condition/finding triggered; no routine calendar cycle. | Reliability + Maintenance / OEM | PA-07 CONDITION-TRIGGERED WO | Event-triggered workflow; no routine cyclic plan | Individual WO | No |
| IN-FG-INS-01 | Fire & Gas Detection / Alarm / Deluge Logic | Fire & Gas Detection / Alarm Visual / Installation Inspection | Use approved route interval based on P-F interval / history; no universal cycle. | Inspection / Asset Integrity | PA-02 INSPECTION / ROUTINE NOTIFICATION | Due-date / single-cycle / strategy notification plan | Notification | Yes |
| IN-FG-CM-01 | Fire & Gas Detection / Alarm / Deluge Logic | Fire & Gas Detection / Alarm Diagnostic / Performance Surveillance | Continuous monitoring + periodic engineering review at approved site interval. | Reliability / Condition Monitoring | PA-01 MONITORING / NO ROUTINE SAP PLAN | No routine SAP plan | None | No |
| IN-FG-FT-01 | Fire & Gas Detection / Alarm / Deluge Logic | Fire & Gas Detection / Alarm Functional / Loop / Performance Test | Per approved proof/functional-test interval; condition can trigger earlier. | Reliability + Discipline | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-FG-CAL-01 | Fire & Gas Detection / Alarm / Deluge Logic | Fire & Gas Detection / Alarm Calibration / Metrological Verification | Per approved metrology / drift-history / criticality calibration interval. | Instrument / Metrology | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-FG-OVH-01 | Fire & Gas Detection / Alarm / Deluge Logic | Fire & Gas Detection / Alarm Condition-Triggered Repair / Restoration | Condition/finding triggered; no routine calendar cycle. | Reliability + Maintenance / OEM | PA-07 CONDITION-TRIGGERED WO | Event-triggered workflow; no routine cyclic plan | Individual WO | No |
| IN-ANALYZER-INS-01 | Online / Laboratory Analyzer | Analyzer Visual / Installation Inspection | Use approved route interval based on P-F interval / history; no universal cycle. | Inspection / Asset Integrity | PA-02 INSPECTION / ROUTINE NOTIFICATION | Due-date / single-cycle / strategy notification plan | Notification | Yes |
| IN-ANALYZER-CM-01 | Online / Laboratory Analyzer | Analyzer Diagnostic / Performance Surveillance | Continuous monitoring + periodic engineering review at approved site interval. | Reliability / Condition Monitoring | PA-01 MONITORING / NO ROUTINE SAP PLAN | No routine SAP plan | None | No |
| IN-ANALYZER-FT-01 | Online / Laboratory Analyzer | Analyzer Functional / Loop / Performance Test | Per approved proof/functional-test interval; condition can trigger earlier. | Reliability + Discipline | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-ANALYZER-CAL-01 | Online / Laboratory Analyzer | Analyzer Calibration / Metrological Verification | Per approved metrology / drift-history / criticality calibration interval. | Instrument / Metrology | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-ANALYZER-OVH-01 | Online / Laboratory Analyzer | Analyzer Condition-Triggered Repair / Restoration | Condition/finding triggered; no routine calendar cycle. | Reliability + Maintenance / OEM | PA-07 CONDITION-TRIGGERED WO | Event-triggered workflow; no routine cyclic plan | Individual WO | No |
| IN-METERING-INS-01 | Metering / Custody Transfer System | Metering / Custody Transfer Visual / Installation Inspection | Use approved route interval based on P-F interval / history; no universal cycle. | Inspection / Asset Integrity | PA-02 INSPECTION / ROUTINE NOTIFICATION | Due-date / single-cycle / strategy notification plan | Notification | Yes |
| IN-METERING-CM-01 | Metering / Custody Transfer System | Metering / Custody Transfer Diagnostic / Performance Surveillance | Continuous monitoring + periodic engineering review at approved site interval. | Reliability / Condition Monitoring | PA-01 MONITORING / NO ROUTINE SAP PLAN | No routine SAP plan | None | No |
| IN-METERING-FT-01 | Metering / Custody Transfer System | Metering / Custody Transfer Functional / Loop / Performance Test | Per approved proof/functional-test interval; condition can trigger earlier. | Reliability + Discipline | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-METERING-CAL-01 | Metering / Custody Transfer System | Metering / Custody Transfer Calibration / Metrological Verification | Per approved metrology / drift-history / criticality calibration interval. | Instrument / Metrology | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-METERING-OVH-01 | Metering / Custody Transfer System | Metering / Custody Transfer Condition-Triggered Repair / Restoration | Condition/finding triggered; no routine calendar cycle. | Reliability + Maintenance / OEM | PA-07 CONDITION-TRIGGERED WO | Event-triggered workflow; no routine cyclic plan | Individual WO | No |
| IN-TEST-EQUIP-INS-01 | Instrument / NDT Test Equipment | Test / NDT Equipment Visual / Installation Inspection | Use approved route interval based on P-F interval / history; no universal cycle. | Inspection / Asset Integrity | PA-02 INSPECTION / ROUTINE NOTIFICATION | Due-date / single-cycle / strategy notification plan | Notification | Yes |
| IN-TEST-EQUIP-CM-01 | Instrument / NDT Test Equipment | Test / NDT Equipment Diagnostic / Performance Surveillance | Continuous monitoring + periodic engineering review at approved site interval. | Reliability / Condition Monitoring | PA-01 MONITORING / NO ROUTINE SAP PLAN | No routine SAP plan | None | No |
| IN-TEST-EQUIP-FT-01 | Instrument / NDT Test Equipment | Test / NDT Equipment Functional / Loop / Performance Test | Per approved proof/functional-test interval; condition can trigger earlier. | Reliability + Discipline | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-TEST-EQUIP-CAL-01 | Instrument / NDT Test Equipment | Test / NDT Equipment Calibration / Metrological Verification | Per approved metrology / drift-history / criticality calibration interval. | Instrument / Metrology | PA-04 CAMPAIGN / PACKAGE WO | Strategy / single-cycle / counter campaign plan | Package WO | Yes |
| IN-TEST-EQUIP-OVH-01 | Instrument / NDT Test Equipment | Test / NDT Equipment Condition-Triggered Repair / Restoration | Condition/finding triggered; no routine calendar cycle. | Reliability + Maintenance / OEM | PA-07 CONDITION-TRIGGERED WO | Event-triggered workflow; no routine cyclic plan | Individual WO | No |
Halaman 10 / 13